What Are the 7 Stages of Cleaning?

Author: Suji Siv
Updated Date: February 19, 2026
Category: Uncategorized
Rate this post

The systematic process integrating Sinner’s Circle principles, chemical action, mechanical action, thermal action, and time factors for effective cleaning and disinfection

The 7 Stages of Cleaning

The 7 stages office cleaning represent a structured, evidence-based process that achieves effective soil removal and microbial reduction through sequential application of four interdependent factors identified in Sinner’s Circle (also called the TACT system): Chemical action (detergents at validated concentrations reducing surface tension and emulsifying oils), Mechanical action (scrubbing, agitation, or pressure removing bonded soil), Thermal action (hot water at 60 to 80 degrees Celsius or steam at 150+ degrees Celsius enhancing chemical and mechanical effectiveness), and Time (dwell periods allowing chemical reactions to complete and mechanical action to loosen bonded contamination). The 7 stages are: (1) Preparation (site assessment, equipment verification, PPE, safety protocols), (2) Pre-Clean (gross soil and debris removal preventing chemical neutralization), (3) Main Clean (detergent application with mechanical action removing bonded soil), (4) Rinse (detergent and loosened soil removal using clean water), (5) Disinfection where required (TGA-listed disinfectants at validated concentrations and contact times killing bacteria, viruses, fungi), (6) Final Rinse where required (disinfectant residue removal from food contact surfaces), and (7) Drying (air drying or wiping enabling safe immediate use and maximizing disinfectant efficacy).

This staged approach is mandatory in healthcare facilities under ACSQHC National Safety and Quality Health Service Standards Action 3.13, in food service under FSANZ Food Safety Standard 3.2.2, in childcare under ACECQA National Quality Framework Quality Area 2, and in aged care under Aged Care Quality Standards. The sequence is not arbitrary — it follows contamination control principles where skipping or reversing stages causes cleaning failure. The most common error is applying disinfectant to uncleaned surfaces where organic load (proteins, fats, biofilms) neutralizes the disinfectant active ingredient by consuming it before it contacts target microorganisms. This reduces kill efficacy from the labeled 99.9 to 99.99 percent down to 50 to 80 percent or lower, allowing pathogen survival and potential transmission.

The 7-stage process integrates physical, chemical, and biological principles: surfactant chemistry (detergent molecules with hydrophilic heads and hydrophobic tails emulsifying oils), mechanical physics (friction overcoming adhesive forces bonding soil to surfaces), thermal kinetics (increased temperature accelerating chemical reaction rates and disrupting microbial cell membranes), and microbiology (disinfectant active ingredients including quaternary ammonium compounds, sodium hypochlorite, alcohol, hydrogen peroxide penetrating microbial cell walls and disrupting protein synthesis or cellular respiration). Understanding why each stage matters enables informed decision-making about when stages can be modified and when they cannot.

Sinner’s Circle: The Foundation of the 7-Stage Process

Before examining the 7 stages, understanding Sinner’s Circle (developed by German chemist Herbert Sinner in the 1960s) provides the theoretical foundation for why the staged approach works. Sinner’s Circle identifies four factors that contribute to cleaning effectiveness: Chemical (detergents and cleaning agents), Mechanical (scrubbing and agitation), Thermal (temperature), and Time (dwell duration). These four factors interact multiplicatively rather than additively — reducing one factor requires increasing others to maintain effectiveness.

For example, reducing chemical concentration by 50 percent requires doubling mechanical action or increasing temperature or extending time to achieve equivalent cleaning outcomes. In practice, commercial cleaning balances these factors based on surface type, soil type, available equipment, time constraints, and safety considerations. Hot water (60 to 80 degrees Celsius) enhances detergent effectiveness and reduces required mechanical action, but creates scald injury risk requiring gloves and training. High mechanical action (pressure washing at 1,500 to 4,000 PSI) removes bonded soil quickly but damages soft surfaces like painted walls or vinyl flooring.

The 7-stage process operationalizes Sinner’s Circle by applying the four factors in optimal sequence. Stages 1 to 4 (Preparation through Rinse) represent the cleaning portion focusing on soil removal. Stages 5 to 7 (Disinfection through Drying) represent the sanitation portion focusing on microbial reduction. Each stage leverages different combinations of the four Sinner factors.

Stage 1: Preparation, Site Assessment, and Safety Protocols

Preparation is the foundation stage that determines whether subsequent stages can be performed safely and effectively. Professional preparation follows a documented checklist covering equipment verification, chemical preparation, PPE selection, site assessment, and safety protocols.

Equipment verification confirms that all required tools are present and functional. Vacuum cleaners are tested for suction (hand placed over intake should create strong pull), power cords are inspected for fraying or damage (creating electrical safety risks under WHS obligations), mop heads are inspected for wear (frayed mop heads indicate replacement needed), spray bottles function correctly (trigger mechanisms tested), and buckets are clean without residual contamination from previous use.

Chemical preparation involves selecting appropriate products for the surface and soil type being cleaned, verifying correct dilution using test strips where concentration verification is required (for example, quaternary ammonium compound test strips verify QAC concentration in ppm, chlorine test strips verify sodium hypochlorite concentration), checking Safety Data Sheets for required PPE and hazard information, and confirming chemical compatibility (never mixing acids with alkalis, never mixing bleach with ammonia which produces toxic chloramine gas).

PPE selection follows Safety Data Sheet specifications. Minimum PPE for most cleaning includes nitrile gloves (resistant to most cleaning chemicals, replacing latex which causes allergic reactions in 1 to 6 percent of population). Additional PPE includes safety glasses or face shields when using spray chemicals at eye level (droplets can contact eyes), cut-resistant gloves when handling waste containing glass or sharps, and chemical-resistant aprons when using concentrated chemicals or high-splash-risk procedures.

Site assessment identifies high-priority areas requiring immediate attention (liquid spills creating slip hazards, heavy contamination, broken glass or sharp objects), areas with restricted access (locked rooms, occupied spaces), and potential hazards (wet electrical outlets, damaged flooring creating trip hazards, pest evidence requiring reporting). This assessment informs cleaning sequence and allows hazard reporting before accidents occur.

Safety protocols include placing caution signage at entry points to areas being cleaned (wet floor signs prevent slip injuries under WHS duty of care), restricting access using barrier tape or closed doors where chemical dwell time requires unoccupied space (preventing chemical exposure to occupants), and ensuring ventilation is adequate for chemical products being used (particularly important for ammonia-based products or high-concentration bleach requiring 8 to 10 air changes per hour).

Preparation typically requires 3 to 7 minutes but prevents time loss during cleaning from equipment failures, missing chemicals, inadequate PPE, or access issues. The Return on Time Investment (ROTI) for thorough preparation is typically 3:1 to 5:1 — every minute spent in preparation saves 3 to 5 minutes during execution by preventing interruptions.

Stage 2: Pre-Clean — Gross Contamination and Debris Removal

Pre-clean removes gross contamination and loose debris before chemical application. This stage is critical because organic matter including food residue (proteins, fats, carbohydrates), grease and oils, body fluids (blood, saliva, urine, feces), biofilms (complex microbial communities embedded in extracellular polymeric matrix), and gross particulate matter (mud, dust, tracked soil) consume disinfectant active ingredients before they contact target microorganisms, reducing kill efficacy from labeled 99.9 to 99.99 percent down to 50 to 80 percent or causing complete disinfection failure.

The mechanism is chemical neutralization. Quaternary ammonium compound disinfectants bind to organic proteins instead of microbial cell walls. Sodium hypochlorite (bleach) is consumed oxidizing organic matter instead of oxidizing microbial proteins. Alcohol-based disinfectants are diluted below effective concentration (requiring 60 to 95 percent ethanol or isopropanol; dilution below 60 percent eliminates antimicrobial activity). Hydrogen peroxide disinfectants are broken down by catalase enzymes in blood and organic matter before contacting target organisms.

Pre-clean methods vary by surface type. For floors, sweeping using commercial brooms or dust mopping using microfibre dust mops removes loose particles without raising dust. For food preparation surfaces, food debris is scraped using plastic scrapers or removed using paper towels (avoiding cross-contamination that cloth towels create). For equipment, loose soil is rinsed using water at ambient temperature (hot water at this stage can ‘cook’ protein-based soil, bonding it more tightly to surfaces).

For heavily contaminated surfaces in food service or healthcare, pre-clean may involve enzymatic cleaners that break down specific soil types: protease enzymes digest protein-based soils (blood, tissue, food proteins), lipase enzymes digest fat-based soils (grease, body oils, dairy products), amylase enzymes digest starch-based soils (pasta, rice, bread residues), and cellulase enzymes digest plant-based soils. These enzymatic cleaners are applied at specific temperatures (typically 35 to 55 degrees Celsius) and pH (typically pH 7 to 9) where enzyme activity is maximum, allowed to dwell 5 to 15 minutes, then rinsed before proceeding to main clean.

Stage 3: Main Clean — Detergent Application and Mechanical Action

Main clean removes bonded soil through combined chemical and mechanical action, integrating two of Sinner’s four factors. Detergents are surfactants (surface active agents) with molecules containing a hydrophilic (water-loving) head and a hydrophobic (oil-loving) tail. This amphiphilic structure allows detergents to emulsify oils and suspend soils in water where they can be rinsed away.

The detergent mechanism proceeds in three steps. First, detergent molecules orient at the interface between water and oily soil with hydrophobic tails penetrating the oil and hydrophilic heads remaining in water. Second, mechanical action breaks large oil deposits into tiny droplets surrounded by detergent molecules (micelles) preventing droplets from recoalescing. Third, detergent-suspended soil is removed from the surface and held in solution until rinsing removes it.

Detergent selection depends on soil type and surface type. Anionic detergents (negatively charged head groups) excel at removing greasy soils and work effectively in hard water but are incompatible with cationic disinfectants (quaternary ammonium compounds) because opposite charges neutralize both products. Non-ionic detergents (uncharged head groups) work in hard or soft water, are compatible with most disinfectants, and are gentle on skin. Cationic detergents (positively charged head groups) have inherent antimicrobial properties but are less effective at soil removal than anionics.

pH influences cleaning effectiveness. Alkaline detergents (pH 10 to 13) excel at removing protein and fat soils through saponification (converting fats to soap) but damage aluminum surfaces and can burn skin requiring gloves. Neutral detergents (pH 6 to 8) are safe for most surfaces and skin but require more mechanical action to remove bonded soil. Acidic cleaners (pH 1 to 4) remove mineral deposits (limescale, rust, hard water staining) but damage marble, limestone, concrete, and other alkali-sensitive surfaces.

Mechanical action applies Sinner’s mechanical factor. Scrubbing using microfibre cloths, non-abrasive pads, or floor brushes applies friction that overcomes adhesive forces bonding soil to surfaces. Pressure washing applies high-pressure water (1,500 to 4,000 PSI) that mechanically dislodges soil. Agitation using floor scrubbers with rotating brushes or pads combines chemical and mechanical action simultaneously.

Dwell time (the third Sinner factor, Time) allows chemical reactions to proceed. Detergent manufacturers specify minimum dwell times on product labels (typically 30 seconds to 5 minutes). Applying detergent and immediately scrubbing without dwell prevents surfactants from penetrating soil, reducing cleaning effectiveness by 30 to 60 percent. Professional cleaners spray detergent, allow specified dwell, then scrub during or after the dwell period.

Temperature (the fourth Sinner factor, Thermal) enhances detergent effectiveness through three mechanisms: increased molecular motion (higher temperature increases collision frequency between detergent and soil), reduced viscosity (oils and greases become more fluid and easier to remove), and enhanced chemical reaction rates (every 10 degrees Celsius temperature increase approximately doubles reaction rates per the Arrhenius equation). Hot water at 60 to 80 degrees Celsius significantly improves grease removal compared to ambient temperature water, though it creates scald risk requiring gloves rated for thermal protection.

Stage 4: Rinse — Detergent and Soil Removal

Rinsing removes detergent residue and loosened soil using clean water. This stage is mandatory for food contact surfaces under FSANZ Food Safety Standard 3.2.2 and for healthcare critical surfaces under ACSQHC standards because residual detergent interferes with subsequent disinfection, creates slip hazards on floors (detergent residue is slippery when wet), leaves visible streaking on glass and polished surfaces, and can cause skin irritation or allergic contact dermatitis in sensitive individuals.

The rinsing mechanism is dilution and physical removal. Clean rinse water dilutes detergent to below effective concentration and physically carries away detergent-soil complexes. For floors, rinsing uses clean water-dampened mops or clean water rinse in twin-bucket systems. For food preparation surfaces, rinsing uses clean water spray or clean water-dampened cloths. For equipment, rinsing uses running potable water at sufficient volume to remove all visible detergent.

Rinse water quality matters. Potable water meeting Australian Drinking Water Guidelines is required for food contact surfaces and healthcare critical equipment because contaminated rinse water reintroduces microorganisms and undermines cleaning and disinfection. Hard water (containing calcium and magnesium ions above 60 mg/L as CaCO3) leaves mineral deposits creating visible water spots on glass and stainless steel. Deionized or reverse osmosis water eliminates mineral deposits and is preferred for streak-free glass cleaning and final rinsing of critical equipment.

In some commercial office environments where disinfection is not performed, rinsing may be omitted if the cleaning product is a low-residue or no-rinse formulation specifically labeled as such. No-rinse cleaners use non-ionic surfactants at low concentrations that dry without visible residue. However, best practice is to rinse after detergent application to ensure complete soil removal and prepare surfaces for disinfection where required.

Multiple rinses may be required for heavily soiled surfaces or when using high-concentration detergents. The first rinse removes bulk detergent-soil mixture. The second rinse removes residual detergent. Visual inspection or test strips verify rinse completion — surfaces should show no foam, feel non-slippery, and (for glass) show no streaking when dry.

Stage 5: Disinfection (Where Required) — Microbial Reduction

Disinfection kills or inactivates bacteria, viruses, fungi, and some bacterial spores on cleaned surfaces using chemical agents (disinfectants) that disrupt microbial cellular function. Disinfection is only performed after surfaces are cleaned because organic load neutralizes disinfectant active ingredients as described in Stage 2.

Disinfection is mandatory in healthcare facilities (ACSQHC NSQHS Action 3.13 requires documented disinfection procedures), food service (FSANZ 3.2.2 Division 4 Clause 19 requires food contact surfaces to be cleaned and sanitized), childcare (ACECQA NQF Quality Area 2 requires documented cleaning and disinfection protocols particularly for nappy change areas and high-touch surfaces), and aged care (Aged Care Quality Standards require infection prevention including environmental disinfection).

In standard commercial offices, disinfection is applied to high-touch surfaces (door handles, light switches, lift buttons, shared equipment) to reduce respiratory and gastrointestinal illness transmission but is not legally mandated. The decision to disinfect is based on pathogen transmission risk, occupant density, and infection control priorities rather than regulatory requirements.

Disinfectant selection depends on target organisms, surface compatibility, contact time constraints, and safety considerations. Common disinfectant classes include:

Disinfectant ClassActive ConcentrationContact TimeSpectrumLimitations
QACs (quaternary ammonium)200-400 ppm general, 400-800 ppm hospital1-10 minutesBacteria, enveloped viruses, fungiIneffective against non-enveloped viruses, spores
Sodium hypochlorite (bleach)500-1000 ppm (0.05-0.1%)30 sec-5 minBroad spectrum including sporesCorrosive, bleaches fabrics, degrades in light
Alcohol (ethanol, isopropanol)60-95% (optimal 70%)30-60 secondsBacteria, viruses, fungiFlammable, evaporates quickly, no residual
Hydrogen peroxide0.5-7%1-10 minutesBacteria, viruses, fungi, spores (high %)Degrades in light, incompatible with some metals
Phenolics500-3000 ppm10 minutesBacteria, Mycobacterium, fungiToxic residue, absorbed through skin, odor

Contact time (dwell time) is the period the disinfectant must remain visibly wet on the surface to achieve labeled kill efficacy. Contact times are determined by manufacturers through laboratory testing against specific organisms per TGA requirements for therapeutic goods. For example, a disinfectant labeled ‘99.99% kill of Staphylococcus aureus in 2 minutes’ has been tested and validated at 2-minute wet contact. Using it at 30-second contact will not achieve 99.99% kill.

The mechanism of contact time relates to disinfectant penetration into biofilms, diffusion to all surface microorganisms, and chemical reaction kinetics. Instantaneous kill does not occur — disinfectants require time to penetrate microbial cell walls, disrupt cell membranes, denature proteins, or interfere with nucleic acid synthesis. Wiping immediately after application removes the disinfectant before these processes complete.

Application technique affects efficacy. Sufficient volume must be applied to keep surfaces wet for the full contact time. In practice, surfaces should appear visibly wet (glistening) throughout the contact period. If surfaces dry before contact time elapses, reapplication is required. This is why ‘spray and walk away’ protocols work — surfaces are left wet and allowed to air dry, ensuring contact time is met or exceeded.

Temperature affects disinfectant efficacy. Most disinfectants are tested and validated at 20 to 25 degrees Celsius room temperature. Lower temperatures (below 10 degrees Celsius) slow chemical reaction rates and may require extended contact times. Higher temperatures (above 30 degrees Celsius) may accelerate reactions but also increase disinfectant degradation and evaporation.

Organic load interference is the primary reason disinfection must follow cleaning. Even small amounts of residual organic matter (1 to 5 percent surface coverage) can reduce disinfectant efficacy by 50 to 90 percent. A surface that appears clean to the naked eye may retain microscopic organic residue that neutralizes disinfectants. This is why ATP bioluminescence testing (measuring adenosine triphosphate as a proxy for organic contamination and microbial load) is used to verify cleaning effectiveness before disinfection in critical environments. ATP readings below 250 RLU indicate adequately cleaned surfaces ready for effective disinfection. Readings above 500 RLU indicate inadequate cleaning requiring re-clean before disinfection.

Stage 6: Final Rinse (Where Required) — Disinfectant Residue Removal

Some disinfectants require a final rinse with potable water after the contact time has elapsed. This removes disinfectant chemical residue that could contaminate food, cause chemical exposure to occupants, or leave visible residue on surfaces.

Final rinse is mandatory for food contact surfaces under FSANZ 3.2.2 when using non-food-contact-approved disinfectants. Many disinfectants contain ingredients that are not approved for incidental food contact (heavy metals, phenols, certain QACs above threshold concentrations). These must be rinsed to prevent food contamination.

No-rinse food contact disinfectants are specifically formulated and approved by FSANZ for use on food contact surfaces without rinsing. These products typically use QACs at lower concentrations (100 to 200 ppm), ethanol (60 to 80 percent), or food-grade hydrogen peroxide (0.5 to 3 percent) at concentrations that leave minimal residue considered safe for incidental food contact. Products must be specifically labeled as ‘no-rinse food contact sanitizer’ or equivalent — a standard disinfectant cannot be assumed no-rinse without explicit labeling.

In healthcare environments, final rinse may be required for patient care equipment in contact with mucous membranes (endoscopes, respiratory therapy equipment) or broken skin where chemical exposure risk exists. The decision depends on the specific disinfectant used and manufacturer specifications in the Instructions for Use (IFU) or Safety Data Sheet.

In standard commercial offices, final rinse is typically not performed after high-touch surface disinfection because disinfectant residue does not create food contamination risk (high-touch surfaces are not food contact) and modern disinfectants dry without visible residue. The exception is when disinfectants contact surfaces that occupants frequently touch with bare skin and then touch food (e.g., shared keyboards in break rooms) — some facilities opt to rinse these surfaces as an extra precaution.

Final rinse technique mirrors Stage 4 rinse. Clean potable water is applied using spray bottles or clean water-dampened cloths, then wiped dry using clean microfibre cloths. For food contact surfaces, running potable water rinse is preferred because it continuously removes disinfectant rather than redistributing it as wiping might.

Stage 7: Drying — Safe Immediate Use and Residual Efficacy

Drying completes the process and leaves surfaces safe for immediate use while maximizing residual disinfectant efficacy. Drying occurs through air drying (surfaces left wet and allowed to evaporate naturally), accelerated air drying (using fans or air movers in high-traffic areas where rapid re-access is required), or wipe drying (using clean dry microfibre cloths).

Air drying is preferred for disinfected surfaces because many disinfectants achieve maximum kill efficacy as they dry. The mechanism relates to disinfectant concentration increasing as water evaporates, creating higher local concentration on the surface that enhances antimicrobial activity. Additionally, air drying ensures that contact time is met or exceeded — surfaces remain wet for several minutes to 15+ minutes depending on humidity, temperature, and air flow, far exceeding typical 30-second to 2-minute labeled contact times.

Wiping immediately after disinfectant application removes the active agent before it completes its work, reducing kill efficacy by 40 to 70 percent in laboratory testing. The phrase ‘spray and walk away’ reflects this principle — apply disinfectant, allow adequate contact time, let air dry, do not wipe. If wipe drying is required for operational reasons (surface must be dry immediately for safety or use), wiping should occur only after the full labeled contact time has elapsed.

For floors, drying prevents slip hazards. Wet floors create fall risk under WHS duty of care obligations in Section 19 of the Work Health and Safety Act 2011. Caution signage must remain in place until floors are dry to touch. In high-traffic areas, air movers (fans rated at 1,000 to 3,000 CFM) accelerate drying from 20 to 40 minutes down to 5 to 15 minutes, enabling rapid safe re-access.

For food contact surfaces, drying prevents water accumulation that could support microbial growth. Standing water in sink basins, on benchtops, or in equipment crevices creates an environment where bacteria multiply rapidly (doubling every 20 to 30 minutes at room temperature). Thorough drying using clean dry cloths or air drying prevents this post-cleaning contamination.

Humidity affects drying time significantly. At 30 percent relative humidity, surfaces dry in 3 to 8 minutes. At 70 percent relative humidity, surfaces require 15 to 30+ minutes. In humid environments (coastal areas, tropical climates, buildings without climate control), air movers or dehumidifiers may be necessary to achieve reasonable drying times.

Why the 7-Stage Sequence Matters: Common Failure Modes

The 7-stage sequence is designed to prevent four common cleaning and disinfection failures observed in environments that skip stages or reverse sequence.

Failure Mode 1: Disinfecting without cleaning. Applying disinfectant to uncleaned surfaces causes organic load neutralization of disinfectant active ingredients. Laboratory studies show that 5 percent organic soil coverage (barely visible to naked eye) reduces QAC disinfectant efficacy from 99.99% kill down to 70 to 80% kill. At 20 percent soil coverage (visibly dirty but not grossly contaminated), efficacy drops to 30 to 50% kill. The pathogens survive, remain infectious, and can transmit to subsequent contacts. This is the most common cause of disinfection failure and healthcare-associated infection transmission in environments with poor cleaning practices.

Failure Mode 2: Not rinsing before disinfecting. Detergent residue remaining on surfaces after main clean interferes with disinfectant action through several mechanisms. Anionic detergents (negatively charged) neutralize cationic disinfectants like QACs (positively charged) through electrostatic binding, rendering both products ineffective. Non-ionic detergents create a film that prevents disinfectant contact with surface microorganisms. Soap residue (saponified fats from alkaline cleaners) coats surfaces in an oily layer that disinfectants cannot penetrate. The result is apparent disinfection (surface was sprayed with disinfectant) without actual disinfection (microorganisms remain viable).

Failure Mode 3: Insufficient contact time. Applying disinfectant and immediately wiping removes the product before chemical reactions complete. This reduces kill efficacy from labeled 99.99% down to 70 to 90%, allowing pathogen survival. In healthcare and food service, this contributes to outbreaks where Environmental Health Officers or infection control auditors can identify that ‘surfaces are being disinfected’ but pathogens are still being cultured because proper contact time is not observed.

Failure Mode 4: Wiping immediately after disinfection. As discussed in Stage 7, wiping before drying removes residual disinfectant and reduces kill efficacy. In operations where staff are trained to ‘wipe down surfaces’ after disinfecting (to prevent chemical exposure or visible residue), the disinfection is partially defeated. The solution is education on spray-and-walk-away protocols or ensuring wiping occurs only after full contact time.

Regulatory and Compliance Context

The 7-stage process is embedded in multiple Australian regulatory frameworks that auditors and inspectors use to assess cleaning compliance.

ACSQHC National Safety and Quality Health Service Standards Action 3.13 requires healthcare facilities to have documented environmental cleaning procedures that specify cleaning methods, cleaning frequency, and monitoring processes. Auditors assess whether cleaning follows a structured sequence (the 7 stages or equivalent) and whether staff can articulate why cleaning must precede disinfection. Non-compliance can result in accreditation issues affecting hospital funding.

FSANZ Food Safety Standard 3.2.2 Division 4 Clause 19 requires food businesses to clean and sanitize food contact surfaces and food contact equipment to the extent necessary to prevent contamination. Environmental Health Officers from councils inspect food businesses and verify that cleaning-then-sanitizing sequence is followed. Non-compliance results in improvement notices, prohibition orders, or prosecution. Officers may use ATP testing or microbiological swabbing to verify that cleaning and sanitization is effective.

ACECQA National Quality Framework Quality Area 2 (Children’s Health and Safety) requires childcare services to ensure the premises, equipment, and furniture are safe, clean, and well-maintained. Assessors verify that cleaning and disinfection follows appropriate sequence for high-risk areas (nappy change surfaces, food preparation areas, mouthed toys). Services must demonstrate documented procedures and staff training on correct sequence.

Aged Care Quality Standards (particularly Standard 8: Organisational Governance) require aged care providers to have systems for infection prevention and control including environmental cleaning. Residential aged care facilities must document cleaning procedures, train staff in correct sequence, and monitor compliance through audits. The Aged Care Quality and Safety Commission conducts assessments and may issue sanctions for poor infection control including inadequate environmental cleaning.

Adaptations for Different Environments

While the 7-stage framework is universal, specific stages are emphasized or de-emphasized based on premises type and risk profile.

Healthcare: All 7 stages are mandatory for critical surfaces (patient care areas, operating theaters, intensive care units). High-touch surfaces receive multiple disinfection cycles daily (three to four times per 24 hours). Contact times are strictly enforced. ATP testing or microbiological monitoring verifies effectiveness. Terminal cleaning (deep cleaning after patient discharge) follows comprehensive 7-stage process with extended contact times (10+ minutes) using sporicidal disinfectants (sodium hypochlorite at 5,000 to 10,000 ppm) for high-risk pathogens like Clostridioides difficile.

Food Service: Stages 1 to 6 are mandatory for food contact surfaces with Stage 6 (final rinse) required unless using no-rinse sanitizers. Food businesses use chlorine test strips or QAC test strips to verify sanitizer concentration in the validated range (50 to 200 ppm chlorine or 200 to 400 ppm QAC). Stage 7 is critical — food contact surfaces must be thoroughly dried because standing water supports microbial growth.

Standard Offices: Stages 1 to 4 are standard for all surfaces. Stages 5 to 7 are applied only to high-touch surfaces. Stage 6 is typically omitted. Disinfectant contact times may be shortened compared to healthcare (30 to 60 seconds vs 2 to 10 minutes) because pathogen load is lower and occupants are generally healthy rather than immunocompromised.

Cleanrooms: All stages are performed but with validated procedures specifying exact products, concentrations, contact times, and monitoring methods. Stages 2 (pre-clean) and 4 (rinse) may use sterile water or WFI (water for injection) rather than potable water. Stage 5 disinfectants are rotated (e.g., QAC one month, alcohol next month) to prevent microbial adaptation. Stage 7 may use HEPA-filtered air or laminar flow to accelerate drying while maintaining particle control.

Summary: Sequential Integration of Cleaning Science

The 7 stages of cleaning represent sequential application of cleaning science principles integrating Sinner’s Circle factors (chemical, mechanical, thermal, time) to achieve effective soil removal and microbial reduction. Stage 1 (Preparation) establishes safety and verifies equipment and chemicals. Stage 2 (Pre-Clean) removes gross contamination preventing chemical neutralization. Stage 3 (Main Clean) applies detergent with mechanical action removing bonded soil through surfactant emulsification. Stage 4 (Rinse) removes detergent residue and loosened soil preparing surfaces for disinfection.

Stage 5 (Disinfection where required) kills bacteria, viruses, and fungi using TGA-listed disinfectants at validated concentrations (QACs 200 to 800 ppm, sodium hypochlorite 500 to 5,000 ppm, alcohol 60 to 95 percent, hydrogen peroxide 0.5 to 7 percent) and contact times (30 seconds to 10 minutes depending on product and organism). Stage 6 (Final Rinse where required) removes disinfectant residue from food contact surfaces under FSANZ requirements. Stage 7 (Drying) enables safe immediate use and maximizes residual disinfectant efficacy through air drying or wipe drying after contact time.

The sequence prevents four common failure modes: disinfecting without cleaning (organic load neutralization), not rinsing before disinfecting (detergent-disinfectant incompatibility), insufficient contact time (inadequate kill efficacy), and wiping immediately after disinfection (removing residual active ingredient). Following the 7 stages in order ensures cleaning effectiveness, enables disinfection to work at labeled efficacy, and complies with regulatory requirements in healthcare (ACSQHC), food service (FSANZ), childcare (ACECQA), and aged care (Quality Standards).

Different environments adapt the framework: healthcare mandates all 7 stages with extended contact times and ATP verification; food service requires Stages 1 to 6 with concentration testing; standard offices use Stages 1 to 4 universally and 5 to 7 for high-touch surfaces; cleanrooms validate all stages with sterile water and HEPA-filtered drying. Understanding the scientific rationale for each stage enables informed application and appropriate adaptation while maintaining effectiveness and compliance.

This guide is provided for informational purposes. Specific procedures vary by premises type, sector obligations (ACSQHC, FSANZ, ACECQA, Aged Care Standards), and cleaning specifications. Professional cleaning companies provide documented procedures, Safety Data Sheets, and training covering the 7-stage process adapted to client requirements and regulatory context. ATP testing and microbiological monitoring verify effectiveness in critical environments.

About the Author

Suji Siv / User-linkedin

Hi, I'm Suji Siv, the founder, CEO, and Managing Director of Clean Group, bringing over 25 years of leadership and management experience to the company. As the driving force behind Clean Group’s growth, I oversee strategic planning, resource allocation, and operational excellence across all departments. I am deeply involved in team development and performance optimization through regular reviews and hands-on leadership.

Read More About Suji
Clean Group - Phone Icon 0291607469 Clean Group - Get a Quote Icon Get A Quote